59 (85) 0. 304LV will fully anneal at 1010-1121°C in just a few minutes. 043 CAR20 2. The material is vacuum re-melted, giving it a more uniform chemistry. 304L Stainless Steel UNS S30403 – 304L is corrosion-resistant up to a maximum temperature. The n gauge wire's cross sercional area A n in square inches (in 2 ) is equal to pi divided by 4 times the square wire diameter d in inches (in):No category World-class solutions in medical-grade materials. A286 5. (MTSCO), MTSCO, Since 2006, China supplier of stainless steel pipe/tube/tubing, seamless steel pipe, welded steel pipe, stainless steel flange, pipe fitting. 304V is the most popular of all our alloys for use in non-implantable medical devices. SURCHARGES Alloy Dec. This article will introduce the differences between 304 and 304L stainless steel (304 vs 304L) from chemical composition, mechanical properties, corrosion resistance and weldability. 1400-1450. The wire gauge indicates the electrical wire sizing, as defined by the American Wire (AWG) system. 719 4. The fill ratio of DFT® wire impacts other mechanical properties. Chrome. 321. Jan. Fatigue Failure Analysis of Enhanced 35N LT®. This alloy has been vacuum arc remelted to yield a more uniform chemistry with minimal. NiTi #1-DFT®-20%Pt. One of the most commonly used titanium alloys is an alpha-beta alloy containing 6% Al and 4% V. 304LV 2. We produce spring wire, electrolytic polished wire, fine wire, wire for netting, hose wire, welding wire, cold heading, locking wire, and other products. Feb. NiTi #1-DFT®-30%Pt. With so many purposes for austenitic stainless steel, it's no wonder it accounts for such a large portion of the overall global market share. Austenitic steels have austenite as their primary phase. End uses include: catheters, guide wires, small parts made from straightened and cut wire and orthodontic uses. Fatigue Failure Analysis of Enhanced 35N LT®. In wire form, cold worked 302 will gain tensile strength when stress relieved at 350-427°C for 4-6 hours. Typical uses include medical devices or implants, aerospace applications and pressure vessels. This stainless steel grade shows good ductility in the annealed condition, and can be readily drawn and formed. Oct. Bundle wiring and protect from abrasion and heat. We produce spring wire, electrolytic polished wire, fine wire, wire for netting, hose wire, welding wire, cold heading, locking wire, and other products. 5V. Wire is typically provided on standard FWM spools (see packaging and spooling data sheet). 395 2. Three examples of possible properties for 35N LT alloy are given below. A286 4. com. The 304LV wire is specially engineered for environments where corrosion resistance is paramount, such as marine, chemical processing, and food processing industries. This practice is followed by Vacuum Arc Remelting (VAR). As annealed (soft) wire is pulled through a die it is reduced in diameter and increases. 304LV will fully anneal at 1010-1121°C in just a few minutes. There is a carbide precipitation phenomenon that occurs between 427 and 899°C that reduces the corrosion resistance of the alloy. Stainless Steel Spring Wire for 304/304L/304M/304H High Quality Wire with High Strength. 4 Ti 6Al-4V ELI Ti 6Al-7Nb Ti 3Al-2. Stainless steel is the most basic medical material. Fatigue Failure Analysis of Enhanced 35N LT®. 847 3. 03%,. 化学成分 力学性能: (以茂辰材质书为准). the manufacturing of medical grade wire. Find many great new & used options and get the best deals for Ulbrich Precision Flat Wire W304LV-7894-1470, 0. In wire form, 304V will gain tensile strength when stress relieved at 350-427°C . Chemistry 304LV Melt Practice. Fatigue Performance of Nitinol Round Wire with varying cold work reductions. chất lượng cao Dây thép không gỉ từ tính thấp để chế biến sâu từ Trung Quốc, Hàng đầu của Trung Quốc Dây thép không gỉ lạnh thị trường sản phẩm, với kiểm soát chất lượng nghiêm ngặt Dây thép không gỉ lạnh nhà máy, sản xuất chất lượng cao Dây thép không gỉ từ tính thấp để chế biến sâu các sản. In other words, as the gauge number gets higher, the diameter of the wire gets smaller. 3 CP Ti Gr. Cyclic Potentiodynamic Survey of Medical Materials. medical material. 003" Wire, 304LV SS, 10,200' at the best online prices at eBay! Free shipping for many products! This austenitic stainless steel is initially electric-arc melted. It is a very strong, safe, and non. Oct. A286 3. AISI 304 and 304L (SS304L) are austenitic stainless steels, and also known as 18/8 stainless steel. This process yields a more uniform chemistry with minimal voids and contaminants. This alloy meets the requirements of 316LS. CP titanium ranges from grade 1, which has the highest corrosion resistance, formability and. June May April Mar. 83 (120) 0. Fort Wayne Metals uses two manufacturing techniques to yield different types of. One of the most commonly used titanium alloys is an alpha-beta alloy containing 6% Al and 4% V. S. 207 1. Oct. Jan. . 0127 mm) to 0. End uses includethe manufacturing of medical grade wire. Sept. Then as a refinement to the purity and homogeneity of the metal, 304LV is Vacuum Arc Remelted (VAR). English;. controlled by a reduced carbon content in 304LV. This stainless steel alloy is a unique nomenclature for Fort Wayne Metals and meets all the requirements of 316LS. Oct. DFT Composite Wire Research; Beta Titanium and Ni-Free SMA Alloys; Super-elastic/Nitinol Alloys; Superalloys; Absorbable Alloys; Magnetic Susceptibility Assessment; Technical Binder 2020; 302; 304LV; 304V; 316 LVM; 35N LT® Custom 455® FWM® 1537; FWM® 1058; DFT® Wire; MP35N® Ti 6Al-4V ELI; Unalloyed Commercially Pure (CP). ในฐานะที่เป็นหนึ่งในผู้ผลิตชั้นนำ 304lv สแตนเลส uns s30400 ซัพพลายเออร์และผู้จัดจำหน่ายในประเทศจีนเรายินดีต้อนรับคุณที่จะซื้อ. Surface roughness can. Type 304L has a carbon maximum is 0. 030 NIS80 17. Nov. Alloy X-750. 302 will fully anneal at 1010-1121°C in just a few minutes. 2023 ULBRICH SHAPED WIRE, INC. 053. 439 2. 383 11. Type 304/304L is a versatile, general purpose stainless steel with good resistance to atmospheric corrosion, and to many chemicals and food and beverages. 304V is the most popular of all our alloys for use in non-implantable medical devices. Ti 6Al-4V ELI. 805 2. You can also compare it with other related products on the same site and find the best deal. Feb. 494 2. 683 4. 022 8020P 3040P 1. 175Suture Wire Stents Guidewires & Delivery Systems Endoscopy And other demanding medical products PRODUCT USES Nitinol (Binary & Ternary) CP Ti Gr. A reducing atmosphere is preferred but inert gas can be used. 8126 Mallory court Chanhassen, MN 55317 . It is a very strong, safe, and non-toxic material with corrosion-resistant properties, being mechanically strong and highly flexible so that it can endure deformation and remain intact. 606 1. 304LV will fully anneal at 1010-1121°C in just a few minutes. Feb. 4307 are also known as grades 304 and 304L respectively. Nov. Fort Wayne Metals offers access to an unparalleled breadth of materials, including round wire, flat wire in a variety of shapes, and centerless precision ground rod, as well as strands and. Overview. 8570 | 1100 1st Street Levelland, TX 79336 Applications ‘The chemistry of 304LV makes it less susceptible to sensitization, (Sensitization is the reduction in a material’ corrosion resistance due to exposure to elevated temp ceratures. Jul. 216 316LV 3. pdf) or read online for free. As a result of extreme compressive forces imparted during the<br />. Ti 6Al-4V ELI. Strip, Coil, Foil & Wire, ASTM A 276, ASTM A 313, ASTM A 666. S. Fort Wayne Metals uses two manufacturing techniques to yield different types of. 808 4. 150" is betterMaterial: Stainless Steel Medical Wire: Grade: 302, 304V, 304LV, 316LVM, Custom 455, Biodur108: Standard: ASTM A313, A313M, A276, F899, A564/A564M, F2229, F138ISO 5832-1Suture Wire Stents Guidewires & Delivery Systems Endoscopy And other demanding medical products PRODUCT USES Nitinol (Binary & Ternary) CP Ti Gr. Jul. 304V is a flexible, robust material that can easily be soldered or welded. the manufacturing of medical grade wire. Flatwire, often referred to as ribbon wire, is commonly used in devices designed to reduce catheter profiles or increase available lumen size. Fort Wayne Metals offers access to an unparalleled breadth of materials, including round wire, flat wire in a variety of shapes, and centerless precision ground rod, as well as strands and. 790 1. Alloy 455 is an alloy melted by several sources. (psi) % Elongation (10" gauge length) 0%. Oct. 907 5. End uses include: catheters, guide wires, small parts made from straightened and cut wire and orthodontic uses. June May April Mar. Nov. Nov. CP titanium ranges from grade 1, which has the highest corrosion resistance, formability and. Description. Expand . Feb. 304LV will fully anneal at 1010-1121°C in just a few minutes. Nov. Standard fill ratios include: NiTi #1-DFT®-10%Pt. Inspection. Nov. 120 2. Sept. MP35N is an excellent combination of strength and corrosion resistance. Shaped Wire Ulbrich Shaped Wire supplies both shaped wire products as well as flat wire to a wide variety of medical device and component manufacturers. ) Because of this feature, 304LV is recommended when exposure to 427-649°C is likely. Il-prodotti kollha tal-azzar huma ta 'kwalità għolja u prezz kompetittiv. Oct. . This results in improved fatigue life of as-drawn wire by as. 304V will fully anneal at 1010-1121°C in just a few minutes. Chromium nickel stainless and heat resisting steel with superior corrosion resistance to other chromium nickel steels when exposed to many types of chemical corrodents; superior creep strength at elevated temperatures. Jan. AISI 304 and 304L (SS304L) are austenitic stainless steels, and also known as 18/8 stainless steel. Alloy 304V is a double melted austenitic stainless steel wire. Our mission is to continually improve the quality of our products, the speed with which we respond to customers’ requests,. Conduit and Conduit Fittings. 972 5. 008" flatness when clamped in a 4-jaw chuck. CP Ti Gr1HP. Ships in three business days. 2022 ULBRICH SHAPED WIRE, INC. DFT Composite Wire Research; Beta Titanium and Ni-Free SMA Alloys; Super-elastic/Nitinol Alloys; Superalloys; Absorbable Alloys; Magnetic Susceptibility Assessment; Technical Binder 2020; 302; 304LV; 304V; 316 LVM; 35N LT® Custom 455® FWM® 1537; FWM® 1058; DFT® Wire; MP35N® Ti 6Al-4V ELI; Unalloyed Commercially Pure (CP). Jan. The distinction lies in the amount of carbon present. 226. 486 15. 824 2. Trademarked by Carpenter Specialty Alloys, this alloy is double vacuum-melted using a vacuum induction melt (VIM) followed by a vacuum arc remelt (VAR). 3 CP Ti Gr. 687. 384 2. Standard fill ratios include: NiTi #1-DFT®-10%Pt. A286 4. 808 4. Typically used in the cold-worked condition, tensile strengths are typically comparable to 304. Alloy 304 is the standard 18/8 (18% chrome, 8% nickel) austenitic stainless steel wire and is the most commonly used grade of stainless steels used in the wire industry. Stainless Steel Spring Wire for 304/304L/304M/304H High Quality Wire with High Strength. This superalloy is initially melted using Vacuum Induction Melting (VIM) techniques. 375 1. Our main materials are stainless steel and alloy steel, and the raw materials we use are from the biggest and most well-known steel mills in China, we can supply wire in sizes ranging from 0. fwmetals. 347. The gauge and diameter of the wire are inversely related. 4301, X5CrNi18-10; 304H, S30415, 1. Alloy 304 is the standard 18/8 (18% chrome, 8% nickel) austenitic stainless steel wire and is the most commonly used grade of stainless steels used in the wire industry. Our main materials are stainless steel and alloy steel, and the raw materials we use are from the biggest and most well-known steel mills in China, we can supply wire in sizes ranging from 0. This practice is followed by Vacuum Arc Remelting (VAR). 304V · 304LV · 316LVM · DFT® (Composites) · 35N LT® · MP35N ® · L-605 (HAYNES 25) · DBS · FWM 1058® · FWM™ 1537 · HASTELLOY ® Alloy C-276 · HAYNES 214™ · 17-7PH® · CUSTOM 455®, 465®, 470® · WASPALOY® · 22Cr-13Ni-5Mn Not all types stocked. ⇐ Stainless Steel 304V/304LV Medical Wire Non-toxic Fine Wire. End uses in the medical field are: pacing leads, stylets, catheters and orthopaedic cables. UNS S30400 304LV Stainless Steel - This low carbon steel is melted with an electric arc, then remelted with a vacuum arc (VAR). The L in 304/L refers to a lower carbon content to allow for greater corrosion protection when welding. VIM/VAR is superior. Select Shape. CP titanium is ordered in relation to the corrosion resistance, formability (ductility) and strength requirements of a specific application. This austenitic stainless steel is initially electric-arc melted. This results in improved fatigue life of as-drawn wire by as. A286 4. 184 9. . A276 304V/304LV Stainless Steel Wire for Medical Fine Wire Medical wire is used in the medical industry as surgical instruments, implants, and devices. Chemistry Physical Properties Thermal Treatment In wire form, 304V will gain tensile strength when stress relieved at 350-427°C. 2022 ULBRICH SHAPED WIRE, INC. 324 3. 304LV stainless steel 316LVM stainless steel Custom 455® alloy High-performance alloys 35N LT™ alloy MP35N® alloy L-605 alloy FWM™ 1058 alloy FWM™ 1537 alloy Titanium2023 ULBRICH SHAPED WIRE, INC. There is a carbide precipitation phenomenon that occurs between 427 and 899°C that reduces the. A reducing atmosphere is preferred, but inert gas can be used. 5991 | 5221 MLK Jr. A286 2. the manufacturing of medical grade wire. This results in improved fatigue life of as-drawn wire by as. Jan. 15mm Bright Surface; Next: Hot Sale 302/3021A Stainless Steel Spring Wire Bright/Matte Surface with ISO certificate Fort Wayne Metals offers various types of medical grade wire that can be transformed into SLT wire. It is a non. In reality, all three are 304 stainless steel based on their chromium-nickel composition, which contains 18% chromium (Cr) and 8% nickel (Ni). Finishes for 316LS Fort Wayne Metals Resource library 304LV Melt Practice This austenitic stainless steel is initially electric-arc melted. Mechanical Properties %CW Y. Wire is typically provided on standard FWM spools (see packaging and spooling data sheet). Steel Wire. 682 12. 304 stainless steel wire is composed of 18% chromium and 8% nickel. Unalloyed Commercially Pure (CP) Titanium is represented by four distinct grades, specifically 1, 2, 3 and 4. Oct. A286 5. Conductor system for implantable devices. In wire form, 304V will gain tensile strength when stress relieved at 350-427°C. CP Ti Gr2. 304LV 2. DFT ® composites were developed to combine the desired physical and mechanical attributes of two or more materials into a single wire or ribbon system. Custom 455 ® is a trademarked name of Carpenter Specialty Alloys. Products. Nov. Download. Our mission is to continually improve the quality of our products, the speed with which we respond to customers’ requests,. 808 4. This low carbon version of 304V Stainless Steel is. 811 0. 08". 2023 ULBRICH SHAPED WIRE, INC. en. Platinum Nitinol DFT® composite wire. 440Type 304/304L is the modern version of “18-8” stainless steel containing approximately 18% chromium and 8% nickel and is the most commonly specified stainless steel used throughout the world. Semua produk keluli mempunyai harga yang berkualiti tinggi dan kompetitif. Stainless Steel 304V/304LV Medical Wire Non-toxic Fine Wire. 304 is a broadly usedcontrolled by a reduced carbon content in 304LV. Our mission is to continually improve the quality of our products, the speed with which we respond to customers’ requests,. 764 5. Standard fill ratios include: NiTi #1-DFT®-10%Pt. Effect of cold work and aging on a Cobalt-Nickel based Alloys. Custom 455. Finishes for 316LS See moreFort Wayne Metals Resource library 304LV Melt Practice This austenitic stainless steel is initially electric-arc melted. An Investigation of Diverse Surface Finishes on Fatigue. We work with and stock a wide range of medical quality alloys, including most stainless steel grades, titanium, titanium alloys, nickel alloys, cobalt alloys and nitinol. Our main materials are stainless steel and alloy steel, and the raw materials we use are from the biggest and most well-known steel mills in China, we can supply wire in sizes ranging from 0. 717 8020P 4. 2 CP Ti Gr. We work with wire diameters from 0. 866 CRMLD. The metal is used in dental and surgical instruments and implants, as it causes no immune response. SURCHARGES Alloy Dec. A probabilistic approach to modeling microstructural fatigue. When the results of the tensile testing on the heat treated tubes are compared to the FWM published data for 304LV it appears that the vacuum and argon heat treatments (at 575 and 655° C. Fatigue Performance of Nitinol Round Wire with varying cold work reductions. Overview. Diameter RangeSuture Wire Stents Guidewires & Delivery Systems Endoscopy And other demanding medical products PRODUCT USES Nitinol (Binary & Ternary) CP Ti Gr. Typical uses include medical devices or implants, aerospace applications and pressure vessels. This alloy, usually referred to as Ti 6Al-4V, exhibits an excellent combination of corrosion resistance, strength and toughness. Due to its unique properties, FWM® 1537 has great potential in any industrial application that requires high strength, wear and corrosion resistance, for instance in aerospace bushings and bearings. End uses includeAbsorbable Whitepapers. AVAILABLE METAL PRODUCT FORMS Coil 304LV Strip 304LV Foil 304LV Ribbon wire 304LV Round Wire 304LV Fine Wire 304LV Flat Wire TEMPERED CONDITION: 304LV can be cold rolled to various tempers. 907 5. 804 3040P 0. 197 2. ) produced mean UTS values that were similar to wire with about 20-30% cold work. Suture Wire Stents Guidewires & Delivery Systems Endoscopy And other demanding medical products PRODUCT USES Nitinol (Binary & Ternary) CP Ti Gr. 3 CP Ti Gr. 15mm Bright Surface; Next: Hot Sale 302/3021A Stainless Steel Spring. When the results of the tensile testing on the heat treated tubes are compared to the FWM published data for. This alloy meets the requirements of 316LS. SLT wire can be produced from the following alloys: - 304V - 304LV - 302 - 301 - 35N LT® - 316LVM - FWM 1058® - TitaniumFort Wayne Metals is a leading manufacturer of medical grade precision materials. DFT Composite Wire Research; Beta Titanium and Ni-Free SMA Alloys; Super-elastic/Nitinol Alloys; Superalloys; Absorbable Alloys; Magnetic Susceptibility Assessment; Technical Binder 2020; 302; 304LV; 304V; 316 LVM; 35N LT® Custom 455® FWM® 1537; FWM® 1058; DFT® Wire; MP35N® Ti 6Al-4V ELI; Unalloyed Commercially Pure (CP). In wire form, cold worked 302 will gain tensile strength when stress relieved at 350-427°C for 4-6 hours. 304L (1. (psi) % Elongation (10" gauge length) 0%. Aug. . June May April Mar. Three examples of possible properties for 35N LT alloy are given below. ,ltd. Applications. SURCHARGES Alloy Dec. There is a carbide precipitation phenomenon that occurs between 427 and 899°C that reduces the corrosion. two or more materials into a single wire or ribbon system. Suture Wire Stents Guidewires & Delivery Systems Endoscopy And other demanding medical products PRODUCT USES Nitinol (Binary & Ternary) CP Ti Gr. Typical uses include medical devices or implants, aerospace applications and pressure vessels. 003" Wire, 304LV SS, 10,200' Sponsored. Suture Wire Stents Guidewires & Delivery Systems Endoscopy And other demanding medical products PRODUCT USES Nitinol (Binary & Ternary) CP Ti Gr. 12/95] Continue to: prev: 11B. For each property being compared, the top bar is AISI 304L. News. O. Typical applications include safety wires in a catheter guidewire, helical coils in a catheter guidewire and braiding wire. DFT Composite Wire Research; Beta Titanium and Ni-Free SMA Alloys; Super-elastic/Nitinol Alloys; Superalloys; Absorbable Alloys; Magnetic Susceptibility Assessment; Technical Binder 2020; 302; 304LV; 304V; 316 LVM; 35N LT® Custom 455® FWM® 1537; FWM® 1058; DFT® Wire; MP35N® Ti 6Al-4V ELI; Unalloyed Commercially Pure (CP). As a leading provider of 304 stainless steel welding wire, we offer a diverse selection of products and wire forming services. the manufacturing of medical grade wire. Alloy 455 is an alloy melted by several sources. Vacuum arc remelting ( VAR) is a secondary melting process for production of metal ingots with elevated chemical and mechanical homogeneity for highly demanding applications. 016 mm) all Fort Wayne Metals routinely works with the followinggrades of surgical steel: 304 (ASTM F899 · ASTM A276 · ASTM A313/A313M);316 (ASTM A276 · ASTM A580 · ASTM 302 · 304LV · 304V · 316LVM · Custom455?UNS S30400 304LV Stainless Steel - This low carbon steel is melted with an electric arc, then remelted with a vacuum arc (VAR). The Significance of Melt Practice on Fatigue Properties. These alloys are made up of between 17 to 20% chromium and between 8 to 15% nickel. Jan. (psi) % Elongation (10" gauge length) 0%. 304LV 1. Find many great new & used options and get the best deals for Ulbrich Precision Flat Wire W304LV-7894-1470, 0. This article will introduce the differences between 304 and 304L stainless steel (304 vs 304L) from chemical composition, mechanical properties, corrosion resistance and weldability. 943 0. In wire form, cold worked 302 will gain tensile strength when stress relieved at 350-427°C for 4-6 hours. ASTM 9260/6150 Spring Wire Oil Quenched-tempered Shaped Wire: ASTM A313 Stainless Steel 304V/304LV Medical Wire For Guide Wires: 304V ASTM A276 Medical Wire Stainless Steel Highly Flexible Wire: ASTM A580/A581 304/304L/304H/304LN Stainless Steel Annealing / Redrawing Weaving Wire For Mesh Wire:In most cases, electrical cords have three wires: the live wire (L), the neutral wire (N), and the ground wire (G). The same publication lists the annealed UTS as 90 ksi and 20% cold worked UTS as 106 ksi. 249 2. 304LV will fully anneal at 1010-1121°C in just a few minutes. com Corporate Headquarters 153 Washington Avenue, P. The fill ratio of DFT® wire impacts other mechanical properties. 617 17. 722 products. 0005” (0. We begin the stainless steel drawing process with our carbide dies for diameters greater than 2. 440 CAR20 4. 1 CP Ti Gr. The melt practice is an enhancement of the standard melt practice for ASTM F-562 material yielding much lower inclusion counts. 216 316LV 4. Effect of cold work and aging on a Cobalt-Nickel based Alloys. Nov. Stainless Steel Wire 304 Annealed-0 Product Stainless Steel 304 Product Guide Stainless Steel Wire 304, the most common stainless steel alloy on earth, provides high strength and good corrosion resistance outside of marine and highly corrosive environments. Chemistry Mechanical properties For more detailed specifications on 304LV please click here. We are FDA registered and ISO 9001, ISO 13485 and AS 9100C certified. Thanks to a large work envelope with extensive. Sept. 003" Wire, 304LV SS, 10,200' at the best. The Significance of Melt Practice on Fatigue Properties. This material is received on spools or coils from our parent company, FWMRPC, at intermediate sizes (~ 1. (Sensitization is the reduction in a material’s corrosion resistance due to exposure to elevated temp-eratures. We produce spring wire, electrolytic polished wire, fine wire, wire for netting, hose wire, welding wire, cold heading, locking wire, and other products. 384 2. 5V Ti-Beta 3 Ti-Beta C 302 304V 304LV 316LVM DFT® (Composites) 35N LT® MP35N® L-605 (HAYNES® 25) DBS® FWM. Alloy 901. Stainless Steel 304V/304LV Medical Wire Non-toxic Fine Wire Medical wire is used in the medical industry as surgical instruments, implants, and devices. Fatigue Failure Analysis of Enhanced 35N LT®. Ti 6Al-4V ELI. SURCHARGES Alloy Dec. This alloy, usually referred to as Ti 6Al-4V, exhibits an excellent combination of corrosion resistance, strength and toughness. Semua produk keluli mempunyai harga yang berkualiti tinggi dan kompetitif. 999Milling 304 Stainless Steel can stink if you aren't sure where to start. . Sept. DFT Composite Wire Research; Beta Titanium and Ni-Free SMA Alloys; Super-elastic/Nitinol Alloys; Superalloys; Absorbable Alloys; Magnetic Susceptibility Assessment; Technical Binder 2020; 302; 304LV; 304V; 316 LVM; 35N LT® Custom 455® FWM® 1537; FWM® 1058; DFT® Wire; MP35N® Ti 6Al-4V ELI; Unalloyed Commercially Pure (CP). 764 5. In wire form, cold worked 302 will gain tensile strength when stress relieved at 350-427°C for 4-6 hours. 648 2. Flatwire, often referred to as ribbon wire, is commonly used in devices designed to reduce catheter profiles or increase available lumen size. Custom 455® has good oxidation resistance at room temperatures, unlike many. 2023 ULBRICH SHAPED WIRE, INC.